Easy return of products

Buy and check it easy at home. Within 14 days, you can return the goods without giving any reason.
View details
14 days for return
Your satisfaction with purchases is the most important. Products ordered from us can be returned within 14 days for any reason.
No stressor worry
Thanks to the integration of our store with cheap returns of the Polish Post you buyno stress and no worries, that the return of the purchased goods will be problematic.
Simplephrase wizard
All returns in our store are handled by simple phrase wizard, which allows you to send us a return parcel.

This product is available in our stores

You can buy this product without placing an online order at one of our stores near you. Check where the product is available immediately.
Check Availability

PACKAGE CONTENT::

  • electrostimulator Nu-Tek Levator Mini LT2051A
  • Nu-Tek NT1041 vaginal probe
  • self-adhesive electrode 5x10 cm - 2 pcs
  • electrode cable - 2 pcs.
  • AAA battery - 4 pcs.
  • case
  • user manual

 

DESCRIPTION:

Nu-Tek Levator Mini is a stimulator for the treatment of various types of urinary incontinence (or stool) and other ailments resulting from weakening of the pelvic floor muscles. The use of the apparatus allows you to restore the ability to control the bladder and improve the patient's quality of life, among others. by improving the sensations during intercourse. Equipment with a vaginal probe and self-adhesive electrodes allows for a therapy tailored to individual needs.

Nu-Tek Levator Mini is a two-channel device, thanks to which it allows to stimulate two independent areas, e.g. vaginally using a probe on one canal and with the use of adhesive electrodes on the skin on the other canal. What is more, the stimulation can be synchronous, i.e. with simultaneous contraction on both channels, or alternately, i.e. consecutive contractions on both channels.

The device is equipped with 20 programs, as well as 2 own programs with the possibility of freely programming the treatment, allowing for:

  • stimulation on two channels in a synchronous or alternating manner
  • stimulation during rest (between contractions) ensuring active rest.

 

DETAILS:

  • two-channel device
  • easy, intuitive operation
  • 20 built-in programs
  • 2 user programs
  • built-in memory of the last 30 treatment sessions
  • great possibilities at a low price
  • keyboard lock
  • automatic switch-off after 2 min. inactivity.

 

VAGINAL PROBE NU-TEK NT1041:

High-quality vaginal probe with electrodes in the form of side plates, for use in EMS electrostimulation of Kegel muscles and EMG biofeedback. The probe works with electrostimulators with cables terminated with a 2 mm pin plug.

The probe is designed for multiple use by one person.

  • unusual lightness
  • ergonomic shape, ensuring easy application and comfort of use
  • sizes: total length: 97 mm, length of the vaginal part: 76 mm, diameter: 27.5 mm
  • large conductive surface in the form of side plates

 

EMS ELECTROSTIMULATION:

EMS neuromuscular electrostimulation is a method in which muscles or motor nerves are stimulated using electrical impulses. The device sends current pulses to the muscles to stimulate them to contract. This method is used for weakened muscles, when the natural mechanism of the nervous system is not able to lead to contractions, among others. in the treatment of urinary incontinence. After just a few weeks, the muscles should be stronger.

Due to the wide range of changes in stimulation parameters, it can be adapted to various requirements and expectations.

After choosing the right program, slowly increase the intensity of electrical impulses and start stimulation. Some programs recommend that you perform contractions on their own or maintain them during the rest (REST) ​​between contractions (WORK) forced by the pacemaker.

To work with this mode, a vaginal probe is used (in the case of urinary incontinence therapy - in men, a rectal probe can be used) or adhesive electrodes glued to the skin in the vicinity of the muscle to be rehabilitated.

One of the studies showing the effectiveness of electrostimulation in urinary incontinence is Female urinary incontinence and intravaginal electrical stimulation: an observational prospective study. In this study, a group of 359 women with urinary incontinence (207 stress urinary incontinence, 33 SAE, and 119 mixed MNM urinary incontinence) were subjected to vaginal electrostimulation for 20–30 minutes a day, 5 days a week for 10 weeks. The test results speak for themselves:


Complete recovery occurred in:

  • 65,7% women witch SUI
  • 57,6% women witch UUI
  • 61,3% women witch MUI

Istotną poprawę zgłosiło: 

  • 14,6% women witch SUI
  • 24,2% women witch UUI
  • 15,1% women witch MUI

Chêne, G., Mansoor, A., Jacquetin, B., Mellier, G., Douvier, S., Sergent, F., … & Seffert, P. (2013). Female urinary incontinence and intravaginal electrical stimulation: an observational prospective study. European Journal of Obstetrics & Gynecology and Reproductive Biology, 170(1), 275-280.

 

PROGRAMS:

  • P1 Urge incontinence in women 1
  • P2 Stress urinary incontinence 1
  • P3 Stress urinary incontinence 2
  • P4 Pollakiuria
  • P5 Stress urinary incontinence - lumbar electrodes
  • P6 Stimulation of the tibial nerve in overactive bladder and fecal incontinence
  • P7 Stress urinary incontinence - buttocks electrodes
  • P8 Mixed / stress / pressure pollakiuria
  • P9 Sensory nerve test to determine the level of current (mA) at which a muscle contraction is felt (needed for program P10).
  • P10 Regeneration of sensory nerves
  • P11 Rectal stimulation for women and men
  • P12 Exercise your pelvic floor muscles to keep fit
  • P13 Maximum explosive exercise for the pelvic floor muscles
  • P14 Pelvic floor muscle strength
  • P15 Weekly Maintenance
  • P16 For new mothers (at least 6 weeks postpartum)
  • P17 After removal of the uterus
  • P18 Stage 1 bladder prolapse
  • P19 Improvement of sexual performance
  • P20 Pain relief
  • PC1, PC2 - programs with freely configured stimulation parameters

 

WHY IS IT WORTH TRAINING THE PELVIC BOTTOM MUSCLES?

Urinary incontinence

Urinary incontinence is a very common disorder in women. Urinary incontinence is defined as the occurrence of involuntary leakage of urine through the urethra.

Sphincter contraction regulates the opening and closing of various channels (urethra, vagina and anus). In the case of a bladder, the pelvic floor regulates the closure of the urethra to prevent urine leakage. This force must be greater than any force that presses against the bladder. Leakage occurs when the pelvic floor is not strong enough. In this case, the sphincter cannot close properly.

Urine leakage can occur for a number of reasons, such as after childbirth or the menopause. To prevent this problem, pelvic floor training is essential throughout your life. The device helps to learn the location of the pelvic floor, perform contractions and strengthen its muscles and properties (elasticity, tonicity, endurance).

 

Intimate life

The pelvic floor plays an important role during intercourse. During the pre-orgasm phase, adequate muscle tone is required to increase sensations during the act, but only relaxation causes orgasm. Therefore, the ability to control the muscles of the pelvic floor is a guarantee of intense sensations.

Weak pelvic floor muscles reduce the sensations during intercourse. On the other hand, too tense muscles can cause pain during intercourse. These two situations can be remedied by practicing proper tone and control of pelvic floor muscle contractions.

 

Improving the condition of muscles after pregnancy and childbirth

The pressure of the uterus and bladder on the pelvic floor, incorrect preparation of the fundus muscles for childbirth, and an incision of the perineum can greatly weaken them and make it difficult to return to normal. Therefore, it is important to learn how to relax your pelvic floor during pregnancy. This will make it easier for the baby to pass through the birth canal and prevent the bladder from weakening, which can cause incontinence problems later.

Technical parameters:
Frequency:
2-100 Hz
Output voltage:
90 V
Guarantee:
24 months (device)
Standard of electrode connection:
pin 2mm
Related Users
Ask for a product:

If the above description is not sufficient for you, please send us your question about this product. We will try to answer as soon as possible.

E-mail:
This field is required to place an order.
Question:
This field is required to place an order.
fields marked with - This field is required to place an order. - are required
IdoSell Trusted Reviews
4.81 / 5.00 975 reviews
IdoSell Trusted Reviews
2023-03-20
Fast and reliable. Very good!!!
2022-11-23
everything ok, except the dispatch delay.
This page uses cookie files to provide its services in accordance to Cookies Usage Policy. You can determine conditions of storing or access to cookie files in your web browser.
I DO NOT AGREE
I AGREE, I WANT TO GO TO THE WEBSITE
pixel